TY - JOUR T1 - Characterizing the Non-Normal Distribution of Flow Cytometry Measurements from Transiently Expressed Constructs in Mammalian Cells JF - bioRxiv DO - 10.1101/057950 SP - 057950 AU - Peter F. McLean AU - Christina D. Smolke AU - Marc Salit Y1 - 2016/01/01 UR - http://biorxiv.org/content/early/2016/06/09/057950.abstract N2 - In mammalian cells, transient gene expression (TGE) is a rapid, minimal-investment alternative to single-copy integrations for testing of transgenic constructs. However, transient gene expression, as measured by flow cytometry with a fluorescent reporter, typically displays a broad, asymmetric distribution with a left-tail that is convolved with background signal. Common approaches for deriving a summary statistic for transiently expressed gene products impose a normal distribution on gated or ungated data. Summary statistics derived from these models are heavily biased by experimental conditions and instrument settings that are difficult to replicate and insufficient to accurately describe the underlying data. Here, we present a convolved gamma distribution as a superior model for TGE datasets. The 4-6 parameters of this model are sufficient to accurately describe the entire, ungated distribution of transiently transfected HEK cells expressing monomeric fluorescent proteins, that operates consistently across a range of transfection conditions and instrument settings. Based on these observations, a convolved gamma model of TGE distributions has the potential to significantly improve the accuracy and reproducibility of genetic device characterization in mammalian cells. ER -