Abstract
Background COVID-19 (coronavirus disease 2019) is a disease caused by infection with the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), affecting millions of people worldwide, with a high rate of deaths. The present study aims to evaluate ultrasound (US) as a physical method for virus inactivation.
Materials and methods The US-transductor was exposed to the SARS-CoV-2 viral solution for 30 minutes. Vero-E6 cells were infected with medium exposure or not with the US, using 3-12, 5-10, or 6-18MHz as frequencies applied. We performed confocal microscopy to determine virus infection and replicative process. Moreover, we detected the virus particles with a titration assay.
Results We observed an effective infection of SARS-CoV-2 Wuhan, Delta, and Gamma strains in comparison with mock, an uninfected experimental group. The US treatment was able to inhibit the Wuhan strain in all applied frequencies. Interestingly, 3-12 and 6-18MHz did not inhibit SARS-CoV-2 delta and gamma variants infection, on the other hand, 5-10MHz was able to abrogate infection and replication in all experimental conditions.
Conclusions These results show that SARS-CoV-2 is susceptible to US exposure at a specific frequency 5-10MHz and could be a novel tool for reducing the incidence of SARS-CoV-2 infection.
Competing Interest Statement
The authors have declared no competing interest.
Footnotes
Materials and Methods section updated; Figures legends updated