ABSTRACT
Introduction Full quantification of positron emission tomography (PET) data requires an input function. This generally means arterial blood sampling, which is invasive, labor-intensive and burdensome. There is no current, standardized method to fully quantify PET radiotracers with irreversible kinetics in the absence of blood data. Here, we present Source-to-Target Automatic Rotating Estimation (STARE), a novel, data-driven approach to quantify the net influx rate (Ki) of irreversible PET radiotracers, that requires only individual-level PET data and no blood data. We validate STARE with [18F]FDG PET and assess its performance using simulations.
Methods STARE builds upon a source-to-target tissue model, where the tracer time activity curves (TACs) in multiple “target” regions are expressed at once as a function of a “source” region, based on the two-tissue irreversible compartment model, and separates target region Ki from source Ki by fitting the source-to-target model across all target regions simultaneously. To ensure identifiability, data-driven, subject-specific anchoring is used in the STARE minimization, which takes advantage of the PET signal in a vasculature cluster in the FOV that is automatically extracted and partial volume-corrected. To avoid the need for any a priori determination of a single source region, each of the considered regions acts in turn as the source, and a final Ki is estimated in each region by averaging the estimates obtained in each source rotation.
Results In a large dataset of [18F]FDG human scans (N=69), STARE Ki estimates were in good agreement with corresponding arterial blood-based estimates (regression slope=0.88, r=0.80), and were precisely estimated, as assessed by comparing STARE Ki estimates across several runs of the algorithm (coefficient of variation across runs=6.74 ± 2.48%). In simulations, STARE Ki estimates were largely robust to factors that influence the individualized anchoring used within its algorithm.
Conclusion Through simulations and application to [18F]FDG PET data, feasibility is demonstrated for STARE blood-free, data-driven quantification of Ki. Future work will include applying STARE to PET data obtained with a portable PET camera and to other irreversible radiotracers.
Competing Interest Statement
Drs. Bartlett, Zanderigo, and Ogden declare no competing interests. Dr. Mann receives royalties from the Research Foundation for Mental Hygiene for commercial use of the C-SSRS.
Nonstandard abbreviations
- STARE
- Source-to-Target Automatic Rotating Estimation