Abstract
Total internal reflection fluorescence microscopy with polarized excitation (P-TIRF) can be used to image nanoscale curvature phenomena in live cells. We used P-TIRF to visualize rat basophilic leukemia cells (RBL-2H3 cells) coming into contact with a supported lipid bilayer, modeling an immunological synapse. These studies help correlate the dynamics of cell surface molecules with the mechanical properties of the plasma membrane during synapse formation.
1. Introduction
The ability of eukaryotic cells to communicate with each other is important for numerous biological processes, including cell growth, motility, and immune function. This communication can occur through soluble factors (cytokines, interleukins, etc.), or by physical cell-cell contact. In the latter case, the immunological synapse is one of the most important communication strategies in immune cells. These intimate cell-cell contacts result in intracellular signaling and is accompanied by large-scale spatial reorganization of membrane proteins within the cell-cell junction. For example, the ability to form a synapse is a well-known communication strategy between T cells and antigen-presenting cells such as B-cells[1,2]. A recent study by Carroll-Portillo and collaborators have shown that mast cells can form a synapse with dendritic cells, and that this can facilitate antigen transfer in T cell activation processes[3]. This suggests to us that mast cells and basophils may play a larger roles in signaling between physically contacting cells.
To study immunological synapse formation we used total internal reflection fluorescence (TIRF) microscopy of fluorescently labeled cells interfacing with a supported lipid bilayer (SLB) containing an appropriate ligand[4]. We have previously demonstrated that rat basophilic leukemia (RBL-2H3) cells possess the machinery to form an immunological synapse in response to antigen-containing SLBs[4–6]. RBL-2H3 cells are derived from rat basophils, but are commonly used in studies of allergic responses which are typically associated with mast cells[7,8]. Similar to mast cells, widely used RBL-2H3 cells degranulate in response to multivalent antigens which crosslink immunoglobulin E (IgE) when bound to its high affinity receptor, FcεRI[8,9]. RBL-2H3 cells can be weakly activated when in contact with fluid lipid bilayers containing monovalent ligands such as dinitrophenol (DNP)[4,10]. In this model system IgE-FcεRI are not cross-linked but aggregate at cell surface protrusions that form the initial contact points with the substrate[6]. After initial IgE-FcεRI cluster formation, small receptor clusters coalesce to form a large central patch, termed the mast cell synapse[4–6]. During activation, RBL-2H3 cells are known to change their morphology, with the cell becoming more ruffled[11]. However a detailed picture of how the transformation of cell membrane shape affects the organization of receptors is still lacking.
Recent studies, for example those summarized in Ref. [12], have focused on identifying proteins that are involved in membrane curvature generation and sensing. In these investigations a surprising abundance of proteins that couple membrane shape to cellular membrane function have been discovered. In this context, we have previously shown that an elevated concentration of curvature-inducing peptides can interfere with the formation of a mast cell synapse in RBL-2H3 cells[13], and it is known that receptor activity at the plasma membrane can be enhanced by membrane curvature changes[14]. To investigate the role of the plasma membrane environment in the formation of immunological synapses in RBL-2H3 cells, we wish to relate the spatial and temporal dynamics of the IgE receptor, FcεRI, with what may be very small changes in cell membrane topography. This can be accomplished using polarized-excitation TIRF microscopy (P-TIRF)[15–24].
We used P-TIRF to determine the relative molecular orientation of the fluorescent lipophilic tracer DiI-C16 in RBL-2H3 cells which were labeled with fluorescent IgE. DiI-C16 inserts into the plasma membrane of cells in a specific orientation such that the chromophore is always oriented parallel to the membrane. The dye is preferentially excited by linearly polarized light according to its orientation. DiI-C16 molecules in areas of the membrane with high curvature in the axial direction are preferentially excited by P-polarized excitation[21]. In a microscope, P-polarized light can be achieved using through-the-objective type TIRF illumination with high NA objective lenses[21], and a ratio of P-polarized excitation and S-polarized excitation images can be used to assess dye orientation and thereby axial membrane curvature[19].
In this study we used P-TIRF to image live RBL-2H3 cells in which we labeled the membrane receptor FcεRI with fluorescent IgE (IgE-488) and labeled the plasma membrane with DiI-C16. We then allowed the cells to settle on and engage supported lipid bilayers containing lipids bearing the IgE ligand DNP. This allows us to correlate receptor patch formation and dynamics with measurements of membrane curvature, while also exploiting the optical sectioning property of TIRF microscopy. We used an innovative optical design and sensitive sCMOS and EMCCD detectors to capture high signal to noise ratio images, which we used to generate P-TIRF ratio images that indicate membrane curvature. These are the first experiments which combine imaging of membrane curvature phenomena with simultaneous imaging of the formation of a model immunological synapse in RBL-2H3 cells that we are aware of.
2. Materials and Methods
2.1 Samples
RBL-2H3 cells, obtained from ATCC (Manassas, VA), were maintained in DMEM supplemented with 10% FCS, 100 U/ml penicillin, and 100 U/ml streptomycin (all from Invitrogen) at 37 °C, 5% CO2, and 100% humidity. Cells were grown in tissue culture flasks, and were transferred to suspension culture petri dishes 24-48 hours before imaging.
We labeled anti-dinitrophenol IgE (anti-DNP-IgE, clone SPE-7, Sigma-Aldrich, D8406) with Dylight 488 NHS ester (Thermo Fisher Scientific, 46403) according to the manufacturer’s protocols (IgE-488). After size-exclusion chromatography, the final dye to protein ratio was typically 5-6 dye molecules per protein molecule as measured with a Nanodrop spectrophotometer (Thermo Fisher Scientific). Cells in suspension culture dishes were labeled with 0.5 nM fluorescent IgE for typically 12-20 hours before imaging.
To label the plasma membrane for P-TIRF measurements, we labeled the cells with 1 μM DiI-C16 (Thermo Fisher Scientific, D384). To prepare the DiI-C16 we dissolved the solid material in ethanol at a concentration of 100 mM, then diluted it to 1 μM in PBS. After 5-10 minutes incubation at 37 °C, we washed the cells with fresh PBS.
We formed liposomes containing 75% 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) and 25% 1,2-dihexadecanoyl-sn-glycero-3-phosphoethanolamine-N-[6-[(2,4-dinitrophenyl)amino]caproyl] (DNP-CAP-PE, Avanti Polar Lipids) by mixing the two components dissolved in chloroform, then evaporating the solvent with a blow-down of compressed air. We then dissolved the mixture in PBS, and sonicated it on ice for 10 minutes using a probe type sonicator (Branson Sonifier 450), until the liposome mixture appeared clear.
To prepare supported lipid bilayers, we pipetted 50 μl of liposome mixture on to a clean petri dish at 37 °C, then overlaid the droplet with a 25 mm #1.5 coverslip that had been cleaned in piranha solution (30% H2O2 in concentrated H2SO4)[25]. After 15 minutes, we immersed the petri dish and coverslip in distilled water, then inverted the coverslip and placed it in a microscope imaging chamber (RC-40LP, Warner Instruments). This prevented the bilayer from coming into contact with air.
2.2 Microscope setup and acquisition
Our setup is based on a DMI300B or DMI8 microscope with an oil immersion HCX PL APO 100×/1.47 NA TIRF objective (Leica, Manheim, Germany). We used an Evolve 512 EMCCD camera (Photometrics, Tucson, Arizona) and micromanager software[26] or a Zyla 4.2+ sCMOS camera with IQ software (Andor, Belfast, Northern Ireland). The TIRF module (custom designed by Spectral Applied Research, Ontario, Canada) uses a liquid crystal polarization rotator and controller (Meadowlark Optics, Frederick, Colorado). The controller is signaled to switch polarizations using an Arduino under the control of micromanager software[27]. The time required to switch polarization states is less than 10 ms, allowing us to record pairs of images with P-polarized and S-polarized excitation with very little delay between the images, and with no moving parts.
Sample fluorescence was isolated with a DV2 image splitter (Photometrics) or with a Lambda 10-B filter wheel (Sutter Instrument, Novato, California) and emission filters appropriate for IgE-488 and DiI-C16 (ET series, Chroma, Bellows Falls, Vermont). For live cell experiments with SLBs, we warmed the objective to 37 °C using an objective heater (Bioptechs). In some experiments we used a custom-made microscope incubation chamber. A diagram and photograph of the microscope setup are shown in Figure 1.
This setup uses a small right-angle prism (legs ~2mm) to steer the laser beam into the back aperture of the objective[28]. A second small right-angle prism steers the reflected beam into a beam dump. This approach eliminates the need for a dichroic mirror. The two prisms, and also one lens, are mounted on stepper-motor actuated stages under computer control. This allows precise and reproducible positioning of the laser beam in the objective back aperture, thereby allowing us to achieve the desired incidence angle (TIRF angle), and therefore the desired penetration depth of the evanescent field. A rotating plate is also stepper motor actuated under computer control and is used for wavelength compensation such that different illumination wavelengths can have the same evanescent field penetration depth. In this setup the azimuthal position of the beam in the back aperture is fixed. This can result in uneven illumination and interference fringes in the image, but this problem was not severe in our case. Spinning the laser beam around the periphery of the back aperture within a single camera exposure can help eliminate such interference patterns[29].
2.3 Membrane Curvature Visualization
A detailed theoretical discussion of the workings of P-TIRF can be found in reference [16]. Briefly, a polarization component of light along the optical axis or the z-axis of the microscope is unique to TIRF microscopy. With epi-illumination, the electromagnetic field propagates along the optical axis and only has components in the x-y plane with respect to the sample. With TIRF illumination, P-polarization results in polarized illumination along the x-axis and the z-axis, with the x-component being about 5% of the z-component. S-polarization results in polarized illumination only along the y-axis. The probability of a fluorophore to absorb a photon is calculated by the dot product of the fluorophore’s excitation dipole and the polarization of the absorbed light. Therefore for fluorophores in which the chromophore is oriented in a specific way, one can determine the orientation of the fluorophore by switching between P-polarized and S-polarized TIRF excitation.
The emission light intensities P and S gathered by an objective from P-polarized and S-polarized excitation are[21] where C = P + 2S is the local concentration of fluorophores, and η(θ) is a factor that describes the orientational distribution of the detected fluorophores. DiI-C16 molecules insert in the membrane with their excitation dipoles parallel to the plane of the membrane[15]. DiI-C16 molecules that are located in areas of the membrane with high axial curvature are excited preferentially by P-polarized excitation in TIRF and a simple ratio R (or ratio image) can be calculated to indicate the local orientation of the cell membrane.
To determine if the excitation intensities are the same for both polarizations, we collected signals (using P- or S-polarized epi-illumination) from DiI-C16 in solution for both polarizations. We found that this ratio for polarized excitation was close to 1.0. Therefore to calculate the ratio we simply divided the P and S images without any additional processing. In some cases we averaged multiple ratio images to reduce noise.
3 Results
3.1 Membrane curvature can be detected using P-TIRF and the dye DiI-C16
We grew RBL-2H3 cells on coverslips overnight, then labeled them with 1 μM DiI-C16. After washing the cells three times with PBS, we imaged them using P-TIRF in PBS or in media in an open-top chamber. We typically recorded 1-40 images in each orientation of polarized excitation, switching the polarization between each acquired image. An example of the results are shown in Figure 2. In this example, large differences are apparent between the two excitation polarizations. Figures 2a and 2b are shown with the same brightness and contrast settings, while Fig. 2c shows a two-color overlay to emphasize the differences. Figure 2d shows an average of 10 ratio images, with the brightness adjusted to a scale ranging from ratios of 0-3. We measured the P/S ratio, Equation (3), in two regions of interest (indicated in Fig. 2d). We found that the ratio was 1.822 ± 0.295 (mean ± standard deviation) in region 1 (high curvature area), and 0.694 ± 0.0661 in region 2 (low curvature, flat area). When creating two-color overlay or ratio images, we measured the lateral shift between the two images using the ‘find shift’ routine within DIPImage[30], an image processing toolbox for MATLAB (The Mathworks, Natick, MA). We found that the shift between the two images was less than about 0.3 pixels in both X and Y. In our case this corresponds to less than 15 nm and so we did not perform an image registration procedure.
Axial membrane curvature is high in filopodia, which are approximately cylindrical and thus have a high aspect ratio[24]. We imaged membrane curvature using DiI-C16 labeled RBL-2H3 cells grown on a coverslip, acquired with the Zyla 4.2+ sCMOS camera. Figure 3a shows an average of 40 P/S ratio images, while figure 3b shows a zoomed-in view of the region of interest indicated in figure 3a. We measured the P/S ratio from top to bottom along the line indicated in Figure 3b, and plotted the results in the inset in the figure.
3.2 Formation of an immunological synapse on a supported lipid bilayer
We next imaged RBL-2H3 cells that had been labeled overnight with DyLight488-IgE as they came into contact with a supported lipid bilayer containing 25% DNP-CAP-PE. As described above, the IgE-488 is bound to cell surface cell surface IgE receptors (FcεRI), and also to DNP-CAP-PE lipids in the bilayer. After 10-15 minutes, we observed a wide variety of model immunological synapses in the form of dynamic patches of labeled IgE receptor. This is shown in figure 4, a gallery of images with various sizes and shapes of IgE receptor patches.
We tested the fluidity of the supported lipid bilayer using a fluorescence recovery after photobleaching (FRAP) method. To do this we labeled the bilayer with a 1% solution of a BODIPY-conjugated lipid (Thermo Fisher Scientific, D3803), and performed a FRAP experiment using a SP5 confocal microscope (Leica) with warmed objective to 37 °C using an objective heater (Bioptechs). Fitting of the fluorescence recovery to a diffusion model yielded a diffusion coefficient of 1.6 μm2/sec. Widefield observations of the BODIPY-labeled bilayer showed that the bilayer was uniform and intact throughout the coverslip surface.
3.3 Imaging of IgE-488 labeled FcεRI with simultaneous imaging of membrane curvature
We next imaged RBL-2H3 cells that had been labeled overnight with IgE-488 and were in contact with a supported lipid bilayer containing a lipid derivatized with the IgE ligand DNP, but in this case the cell membrane was also labeled with DiI-C16. This experiment is shown in Figure 5. We observed in many cases that ‘holes’ in the FcεRI patch are evident (for example in Fig 5i), but that these holes are not devoid of cell membrane (Fig 5j). We further analyzed the images by segmenting the image so as to create masks (see supplemental Fig. S1) corresponding to regions containing IgE-bound FcεRI (+IgE) or lacking IgE-bound FcεRI (−IgE), then plotted normalized histograms of the number of pixels with particular P/S ratios in +IgE and −IgE regions (Fig 5d,h,l). Membrane regions containing IgE-bound FcεRI consistently had lower P/S ratios than those regions lacking the receptor, though this varied considerably from cell to cell. For each cell shown in Figure 5, a two-sample Kolmogorov-Smirnov test was performed using the statistics toolbox within MATLAB. For all cells, the test rejected the null hypothesis that P/S ratios in +IgE and −IgE regions come from populations with the same distribution at the 5% significance level.
3.4 Time-Lapse imaging of a model immunological synapse
Finally, we imaged RBL-2H3 cells in contact with a supported lipid bilayer over the course of about 4 minutes. We observed that the IgE-488 bound FcεRI formed a dynamic patch which continually changed shape. Figure 6 shows time-lapse imaging of IgE-488 bound FcεRI and a two-color overlay of P-polarized excitation and S-polarized excitation signals from DiI-C16. 10 time points out of 108 total are shown. Supplementary Video S1 shows the entire image sequence.
4. Discussion
The relationship between membrane curvature phenomena and the organization of cell surface receptors responsible for signaling in RBL-2H3 cells has not been well explored. Here we used P-TIRF microscopy to image a model of immunological synapse formation in live RBL-2H3 cells. We detected membrane curvature using a fluorescent probe that exhibits a specific orientation in the plasma membrane, and correlated this with the organization and dynamics of the IgE receptor. Membrane regions containing IgE-bound FcεRI consistently had lower P/S ratios than those regions lacking the receptor, indicating that regions lacking the receptor are more curved than regions containing the receptor within the cell-substrate contact zone.
In the future, to help reveal the nature of the curvature features we detect, live cell super-resolution microscopy will be valuable. Structured illumination microscopy[31,32] would allow imaging of receptor patch formation with super-resolution, and single molecule localization microscopy methods[33,34] would allow evaluation of nanoscopic membrane features in relation to IgE receptor dynamics.
Author Contributions
Conceptualization, K.S.; Formal analysis, R.M., K.S. and G.M.H; Funding acquisition, K.S. and G.M.H.; Investigation, R.M., J.B., M.B. and G.M.H.; Methodology, K.S. and G.M.H.; Supervision, K.S. and G.M.H.; Visualization, R.M. and G.M.H.; Writing - original draft, K.S. and G.M.H.; Writing - review & editing, K.S. and G.M.H.;
Funding
Research reported in this publication was supported by the National Institute of General Medical Sciences of the National Institutes of Health under award number 1R15GM128166-01 and by the National Science Foundation under Grant Number 1727033. This work was also supported by the University of Colorado Colorado Springs (UCCS) center for the University of Colorado BioFrontiers Institute and by the UCCS Committee for Research and Creative Work grant.
Conflicts of Interest
The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the authors and do not necessarily reflect the views of the National Science Foundation.